Product Quick Selection Wheel

CAMTEC - 240W (312W) DIN Rail Power Supply HPW02401 SERIES

Features
  • 240 Watts Power Supply
  • DIN Rail 35mm. Metal housing
  • 91.5% efficiency. -25°C...+70°C ambient
  • Free air convection
  • Continuous short circuit protected
  • Overload & low voltage protected
  • Soft start & auto-recovery
  • EMI/EMS EN61000-6-2/3. EN55022 class B
  • Active PFC: EN61000-3-2
  • Low voltage & overload control message
  • Remote ON/OFF
  • High reliability. Shock & vibration resistant

HPW02401 SERIES

Product Overview

CAMTEC - HPW02401 SERIES 

240W (312W) Power Supply with active PFC & active inrush protection  

Available Outputs:   9-18V,   18-30V,   30-43V,   53-72V,   68-86Vdc  

Description   The HPW02401 DIN Rail power supply series is designed for worldwide electronics applications like machine building, railway, military and factory automation. Its regulated DC output with ripple/noise lower than 30mVpp and its high efficiency of 91.5% makes the HPW robust, economical and reliable. Camtec power supplies are tradionally made with high end low ESR electrolytic output capacitors with withstanding +125°C temperature. Our capacities are rather designed over for longer lifetime and longer hold up times. The power boost of the HPW starts DC-loads and DC-motors reliable. The built in function diagnostics detects malefunctions. The galvanic insulated DC fail relay and remote on/off provides full control over the power supply unit. The HPW is short circuit and zero load stability protected. It is protected against high transient and provides very good interference resistance. Equal types of the HPW02401 can be operated in parallel or in series connection. We use IP20 stabile aluminium hausings with vantilation slots in accordance to the demanding VDE norms. The design meets EN (IEC)60950-1 and low voltage directive EN55022 Class B.

Specifications

GENERAL
Output Voltage See selection table
AC Input Voltage 85..132Vac / 184..265Vac
Frequency 47…63Hz
DC Input Voltage 90…350Vdc
AC Input Current 115Vac <2.6A 230Vac <1.3A
AC Input Current 115Vac <2.6A 230Vac <1.3A
Tolerance Ua adjusted ± 0.5%
Transient Time <1ms (10-100% , 100-10%)
Minimum Load 0 A
Efficiency 91.5% typical
Load Protection 1,2x I rated , auto recovery
Short Circuit Protection Yes
Temperature Controlled Yes (see technical illustrations)
Temperature Controlled Yes (see technical illustrations)
Hold Up Time > 40ms (100...230Vac input)
Inrush Current < 7A (230Vac), active limiter
Softstart 50ms typical
RELIABILITY
Air & Surface Leakage Paths > 8mm
Input/Output Galvanic insulated
DC Fail Relay (galv. insulated) ≤48Vdc/500mA , ≤30Vac/500mA
MTBF (IEC61709) 500000h
ENVIRONMENTAL
Cooling Natural convection
Ambient Temperature - 25°C…+70°C
Storage Temperature - 40°C…+85°C
Relative Humidity 95% (25°C) non-condensing
Pollution Degree 2 (EN50178)
Climatic Class 3k3 (EN60721)
STANDARDS AND APPROVALS
EMI EN55022 class B / EN61000-3-2
EMS EN61000-6-2,3 active PFC
Safety EN60950-1, EN60204-1
Safety class 1(A) VDE0805, VDE0100
MECHANICAL
Dimensions (HxWxD) 130x75x115mm
Weight 1200g
Connectors (AC & DC) AWG20...AWG6 IEC60664-1, IEC61984

Selection Table

DIN RAIL MODEL HPW02401.12T HPW02401.24THPW02401.36THPW02401.48T HPW02401.60THPW02401.72T
Rated DC Voltage 12Vdc 24Vdc 36Vdc 48Vdc 60Vdc 72Vdc
DC Voltage Adjust 9...18Vdc 18..30Vdc 30...43Vdc 43...53Vdc 53...72Vdc 68...86Vdc
Over Voltage Protection 21Vdc 35Vdc 50Vdc 60Vdc 84Vdc 97Vdc

Rated Current 60°C

15.0A 10.0A 6.7A 5.0A 4.0A 3.3A

Rated Current 40°C

19.0A 13.0A 8.7A 6.5A 5.2A 4.3A

Boost 60s/60°C

18.0A 12.0A 8.0A 6.0A 4.8A 4.0A

Ripple mVpp/230Vac

30 (20MHz) 30 (20MHz) 60 (20MHz) 50 (20MHz) 50 (20MHz) 60 (20MHz)

Load regulation 0-100%

±0.5% ±0.2% ±0.2% ±0.2% ±0.2% ±0.2%
WALL MOUNT MODEL HPW02401.12W HPW02401.24WHPW02401.36WHPW02401.48W HPW02401.60WHPW02401.72W
Rated DC Voltage 12Vdc 24Vdc 36Vdc 48Vdc 60Vdc 72Vdc
DC Voltage Adjust 9...18Vdc 18..30Vdc 30...43Vdc 43...53Vdc 53...72Vdc 68...86Vdc
Over Voltage Protection 21Vdc 35Vdc 50Vdc 60Vdc 84Vdc 97Vdc

Rated Current 60°C

15.0A 10.0A 6.7A 5.0A 4.0A 3.3A

Rated Current 40°C

19.0A 13.0A 8.7A 6.5A 5.2A 4.3A

Boost 60s/60°C

18.0A 12.0A 8.0A 6.0A 4.8A 4.0A

Ripple mVpp/230Vac

30 (20MHz) 30 (20MHz) 60 (20MHz) 50 (20MHz) 50 (20MHz) 60 (20MHz)

Load regulation 0-100%

±0.5% ±0.2% ±0.2% ±0.2% ±0.2% ±0.2%

Optional Coating (option C): We offer the HPW-Series with optional coating. It is to be used in e.g. dusty, dirty, high humidity, or in awaiting quick temperature changes. Short circuit and corrosion at print board lines and at solder points can be prevented. The coat itself is a transparent acrylic resin. It is procured with a robotics varnishing machine. Peters SL 1306 N-FLZ (transparent) IEC60216-1 2001, IPC-CC-830B, UL listed as permanent coating FileNo.: E80315 , UL94V-0

Options to be added to the order-code:

C coating

Order samples:

HPW02401.24TC DIN-Rail+Coating

HPW02401.24WC Wallmount+Coating

Technical Illustration

Back to Top

Ask Your Question