Product Quick Selection Wheel

CENTAUR SERIES CENTAUR - Victron Three Step Charger

Features
  • 240W - 1440W
  • 12V and 24V Battery Systems
  • Three Step Charger
  • Temperature Compensation
  • Three Separate Outputs
  • Charge 3 battery banks
  • Corrosion Resistant

CENTAUR - Victron Three Step Charger

Product Overview

Centaur Three Step Battery Charger 

Centaur Charger The Centaur range of battery chargers features auto-ranging input covering 90-265VAC 50/60Hz input meaning they can be used anywhere in the world. Crucially, and unlike many other products that state universal input, the Centaur range will maintain full output power within the entire specified range. Other features include fully automatic three stage charge characteristic that ensures batteries are fully charged every time and three isolated charge outputs for multi battery configurations to suit the majority of typical installations. The range spans 12V and 24V models from 16A through to 100A.. Models: 12 / 24 Volt

Quality without compromise Aluminium epoxy powder coated cases with drip shield and stainless steel fixings withstand the rigors of an adverse environment: heat, humidity and salt air. Circuit boards are protected with an acrylic coating for maximum corrosion resistance. Temperature sensors ensure that power components will always operate within specified limits, if needed by automatic reduction of output current under extreme environmental conditions.

Universal 90-265V AC input voltage range and also suitable for DC supply (AC-DC and DC-DC operation) All models will operate without any adjustment needed over a 90 to 265 Volt input voltage range, whether 50 Hz or 60 Hz.

The chargers also accept a 90-400V DC supply.

Three outputs that each can supply the full output current Three isolated outputs to simultaneously charge 3 battery banks Each output is capable to supply the full rated current.

Three stage charging, with temperature compensation The Centaur charges at bulk rate until the output has reduced to 70 % of the rated Amps, at which a 4 hour timer begins. After the timed period the charger switches to float rate. An internal temperature sensor is used to compensate the charge voltage with – 2 mV/ºC (– 1 mV/ºF) per cell. A dip switch is available to select the optimum charge/float voltages for Flooded Lead-acid, Gel or AGM batteries.

Specifications

INPUT
Input voltage

90 - 265Vac

90 - 400Vdc

Input frequency 45 - 65Hz
Power factor 1.0
BATTERY CHARGING OUTPUT

Battery Charging

Optimum  absorption charge and float voltages for Flooded Lead-acid, Gel-Cell or AGM batteries.  Selectable by dip switch

Absorption

Charge voltages

14.3Vdc and 28.5Vdc

See selection table

Float

Charge voltages

13.5Vdc and 27.0Vdc

See selection table

Three outputs 3 isolated outputs that each can supply up to the fully rated current. Combined total rated current cannot be exceeded. Keeping within the total power rating of the battery charger.
Total output ammeter Yes.
Charge characteristic Charges at the absorption rate,  until the output has reduced to 70% of rated current.  At which time a 4hour timer begins, then the charger switches to float rate
Temperature sensor Internal, -2mV/°C per cell.
Battery Monitor The BMV-700 battery monitor features an advanced control and measuring system for battery voltage and charge/discharge current. The battery monitor displays battery voltage, current, consumed AH or time to go.
Battery Alarm An excessively high or low battery voltage is indicated by an audible and visual alarm
PROTECTION
Ignition protected Yes.
Short circuit protection Yes.
Over temperature
protection
Yes.
STANDARDS
Safety EN60335-1, EN60335-2-29, UL1236.
Emission Immunity EN55014, EN61000-3-2
Automotive Directive EN55012-2, EN61000-3-3
C-tick AS/NZS CISPR11: Group 1, Class A.
ENVIRONMENTAL
Operating temperature -20°C to +60°C.
Derating Full load up to 40C ambient, Output will reduce to approximately 80% of nominal at 50C and 60% of nominal at 60C
Cooling Temperature and current controlled fan.
Humidity 95% max (non condensing).
MECHANICAL
AC connection Screw-clamp 4mm² (AWG 6)
Battery connection

M6 or M8 studs

See selection table

Protection category IP21.
Material & colour Aluminium epoxy powder coated cases (blue RAL 5012), Stainless steel fixings
Size & Weight

12/20-12/30: 355 x 215 x 110mm, 3.8Kg

12/40-12/60, 24/30: 426 x 239 x 135mm, 5Kg

12/80-12/100, 24/40-24/60: 505 x 255 x 130m, 12Kg

12/200, 24/80-24/100: 505 x 255 x 230mm, 16Kg

Selection Table

MODEL NUMBER

ABSORPTION

CHARGE

VOLTAGE

FLOAT

CHARGE

VOLTAGE

OUTPUT

CURRENT

BATTERY

CONNECTION

RECOMMENDED

BATTERY SIZE

Centaur 12/20 14.3V

13.5V

20A M6 studs 80-200Ah
Centaur 12/30 14.3V 13.5V 30A M6 studs 120-300Ah
Centaur 12/40 14.3V 163.5V 40A M8 studs 160-400Ah
Centaur 12/50 14.3V 13.5V 50A M8 studs 200-500Ah
Centaur 12/60 14.3V 13.5V 60A M8 studs 240-600Ah
Centaur 12/80 14.3V 13.5V 80A M8 studs 320-800Ah
Centaur 12/100 14.3V 13.5V 100A M8 studs 400-1000Ah
Centaur 24/16 28.5V 27V 16A M6 studs 45-150Ah
Centaur 24/30 28.5V 27V 30A M8 studs 120-300Ah
Centaur 24/40 28.5V 27V 40A M8 studs 160-400Ah
Centaur 24/60 28.5V 27V 60A M8 studs 240-600Ah