Product Quick Selection Wheel

B4500 SERIES B4500 - Schaefer Euro Series Battery Charger

Features
  • 900 - 1600W
  • Battery Charger Industrial Grade
  • Temperature Compensated
  • Auto and Manual Selection of Float
  • Equalize and Charge
  • Configurable Options
  • Eurocassette Mounting
  • Wall Mounting
  • Chassis Mounting

B4500 - Schaefer Euro Series Battery Charger

Product Overview

 

Schaefer High Output Voltage Power Converters.

Schaefer Electronics robust design, using industrial grade components, yields a highly efficient, space-saving 6U solution for even the most extreme environments.

The Schaefer’s C/B4500 Series, offers an extensive lineup of over 150 standard models. Standard DC input voltage options span a range from 10VDC to 800VDC. AC input models offer either 1-Phase or 3-Phase options as well as battery charging models. Single output voltages encompass a range from 9VDC to 400VDC, all of which are adjustable and fully regulated to 0.2% or better (load) and 0.1% (line).

Remote sense capability and comprehensive protection circuitry is inherent in the design, with efficiencies up to 90%. Operating temperature is -20C to +75C, with -40C to +75C as an option. Additional options include parallel / redundant operation, further mechanical ruggedization, inhibit, Power-OK / DC-OK alarms, and system reset.

Specifications

INPUT
Input voltage

1ph 115/230Vac

3ph 200/400/480Vac

See selection table

Units will turn off with under or over input voltage.

No-load input
power
3-6W model (series dependant)
Inrush current AC input limited by thermistor
Switch on time 1-2 seconds.
Input Options

Option au: Autoranging for 115/230Vac input

Option pr: Power OK via relay contacts

OUTPUT
Output voltage

Voltage range; 4.5 - 400Vdc

See selection table

Output current See selection table.
Ripple & noise 1% + 30mVpp
Line regulation 0.1% (±10%)
Load regulation 0.2% typical, load step 10-90%
Load transient 6% typical, load step 10-90%
Response time 2-3ms typical ±1%
Temperature coefficient 0.02% per °C typical.
Holdup time 10mS at 220VAC typical
Turn on rise time 100mS typical (soft start)
Remote sensing Standard for all series
Efficiency 80%-92% typical
Output Options

Option dd: Decoupling Diode for redundant / parallel operation

Option cs: Active Current Sharing

Option h: Remote on/off (inhibit)

Option dr: DC OK via relay contacts

Programming Options: See selection table

PROTECTION
Overload protection Current limited at 105%–110% of full load.
Overvoltage protection OVP switches off module with automatic return to operation
Protection Options

Option i: Inrush Current Limiting

Option sd: Reverse polarity protection for DC input by Series Diode

MTBF

100Khrs to 140Khrs at 40°C

acc. to MIL-HDBK-217E (notice 1)

ENVIRONMENTAL
Operating temperature

-20°C to +75°C

(optional -40 to 75C)

Load derating Derate 2.5% per °C, from +55°C to 75°C
Cooling

H: Heatsink - natural convection

F: Fan - increased airflow recommended

TF: Temperature controlled Fan included

See selection table

Environment Options

Option c: Extended temperature range to -40°C

Storage temperature -40°C to +85°C
Humidity Up to 95% RH, non-condensing
STANDARDS
EMI standards acc. to EN61000-6-4 class A, optionally class B
Immunity standards acc. to EN61000-6-2
C-Tick AS/NZS CISPR11: 2002 Group1 Class A
Safety / Construction acc. to EN60950-1 / EN50178
Protection category

IP20 acc. to EN60529

NEMA or others on request

MECHANICAL
Mounting

See technical illustrations

Eurocassette, pluggable module for 19" subrack

Option w: Wall Mounting

Option cha: Chassis Mounting

Dimensions See Technical illustration
Connector

H15 acc. to DIN 41612 H15

and high current connectors for I > 50A,

or terminals / bolts / bars

Mechanical Options

Option ms: Increased Mechanical Strength

Option t: Tropical protection

19" Rack Mounting

Options

Subrack Height 3U, 5U, 6U

Wiring, Front Panels

Accessories: Fuses, MCBs, Mains on/off switch

Contact Powerbox for rack configuration

Selection Table

INPUT

115VAC

± 20%

INPUT

230VAC

+15% - 20%

INPUT

115 ± 20%

230VAC+15% 20%

INPUT

3X200VAC

+15% - 20%

INPUT'

3X400VAC

+15% - 20%

INPUT

3X480VAC

+15% - 20%

          

OUTPUT

AMPS

         

BATTERY

CHARGER

VOLTAGE

VOLTAGE

ADJ. RANGE

B4561 B4581 B4591 B4561V B4581 V B4591V   80   12 12-16
B4562 B4582 B4592 B4562V B4582 V B4592V   46   24 24-32
B4564 B4584 B4594 B4564V B4584 V B4594V   25   48 48-64
B4566 B4586 B4596 B4566V B4586 V B4596V   20   60 60-80
B4567 B4587 B4597 B4567V B4587 V B4597V   12   110 110-145
B4568 B4588 B4598 B4568V B4588 V B4598V   6   220 220-290
Cooling

H: Heatsink - natural convection

F: Fan - increased airflow recommended

TF: Temperature controlled Fan included

See selection table

Model configuration options:

Add the options to the model number, eg. B4588-dd-dr-cs

Options for Input, Output, Environmental and Mechanical follow.

19" Rack Mounting Options

Subrack Height 3U, 5U, 6U

Wiring, Front Panels

Accessories: Fuses, MCBs, Mains on/off switch

Contact Powerbox for rack configuration

OPTIONS
INPUT
Option “i” (inrush current limiting): A thermistor is connected in series with the
input lines which changes its resistance from high to low when it gets hot. It does
not reduce the current surge if the input power is interrupted for a short period of
time not allowing the thermistor to cool down. Thermistors are fitted as standard
to all mains input models except for 1-phase input of models > 2.5kW.
Thermistors are available up to 45A. For higher input current an electronic inrush
current limitation can be offered.
Option “ie” electronic inrush current limiting An electronic circuit limits the inrush
current.
Option “sd” (series diode): A series diode protects the module against input
voltage of wrong polarity (additional power losses).
Option “ad” (anti-parallel diode): To avoid the power losses of a series diode a diode is
provided with opposite polarity in parallel to the input blowing an internal or external
fuse if the module is connected to a supply with wrong polarity.
Option “au” (auto-ranging) For standard dual AC input models the range of
115/230Vac is to be selected by connecting the input line to different pins on the
connector. With auto-ranging the unit senses the input voltage and provides
automatically the correct connection.
Option “p” (power fail): A signal (logic or relay) is given if the input voltage (AC or
DC) drops below the specified limit. In AC input units we sense the rectified input
voltage so that a power fail alarm will not be triggered if at light loads mains
power returns before the input capacitors are substantially discharged.
Option “r” (relay): A relay instead of a logic signal is provided for failure indication.
output
Option “dd” (decoupling diode): For redundant operation the outputs of two or
more units are paralleled behind de-coupling diodes so that an internal fault of
one module does not affect the operation of the others. These diodes cause power
losses.
Option “cs” (active current sharing): An additional control circuit provides active
current sharing via an interconnecting wire between converters that operate in
parallel. Active current sharing should be used for multi-output units operating in
parallel.
Option “csi” (current sharing interrupt): Option "csi" will effect the removal of the
"cs" signal. Should there be an instance where a unit is not supplying the load,
then the effect of its "cs" signal is removed, and the load voltage is unaffected by
this condition.
Option “h1” (inhibit): A terminal connected to the negative input line also shuts off the
converter. This can also be used in conjunction with a thermal trip which shuts the unit
down.
Option “h2” (inhibit): Operation of the unit is inhibited if a voltage signal
(5V/10mA) is applied in reference to the negative line of the (main) output.
Option “rco” (reducing current limiting at over temperature) A circuit reduces the
current limiting level at higher temperature (to be specified).
Option “d” (DC-ok, one output): A logic signal is given if the output voltage (main
output in multi-output systems) is below the specified limit.
Option “m” (DC-ok, all outputs): In multi-output systems a logic signal is provided
if the voltage of any output is below the specified limit.
Option “ac” (AC ok) A logic signal connected to relay contacts is given if the
output voltage of an inverter is below the specified limit.
Option "y" (sys-reset): This logic signal is a combination of power fail and DC-ok
as specified for VME systems.
Option "r" (relay): A relay instead of a logic signal is provided for failure
indication.
CHARGER PROGRAMMING
Option "tc" Temperature compensated charging voltage(sensor not included)
Option "ts1" Temperature sensor, not interchangeable due to fixed resistor values
Option "ts2" Interchangeable, IC controlled
Option "ch1" Automatic selection of charging characteristic (float / equalize charge) with timer
Option "ch2" Additionally: Manual selection of charging characteristic
Option "ch3" Additionally: Boost charge operation (manually activated with
time delayed return to normal operation)
environment
Option "t" (tropical protection):The unit is given additional protection by a heavy
coat of varnish on the printed circuit board(s) and components.
Option "c" (extended temperature range):The circuit is designed and tested for
operation at an ambient temperature as low as –40 °C.
Option "ms" (increased mechanical strength): Screws are secured by Locktite and
heavy components are fastened by ties and/or glue. Modules with the "ms" option
meet the standard EN61373 regarding shock and vibration.
mechanics
Standard mounting "Eurocassette" pluggable module for 19" sub-racks 8
Option "w" (wall mounting): Module is screwed against a mounting plate for
installation in a cabinet. The load connections are typically a terminal block.
Option "cha" (chassis mount) Module is designed for installation to a structure or
within cabinet. Screw type connectors are supplied with the module.
Option "din" (DIN rail mount) Module is designed for DIN rail mounting to a
structure or within Cabinet. Screw type connectors are supplied with the module.

Technical Illustration

  • B4500 B4500
Back to Top

Ask Your Question