BATTERY CHARGER Skylla-IP44 Battery Charger

Features
  • IP44 Battery Charger
  • Models: 12V/60A & 24V/30A
  • Skylla-IP44 (1+1): two outputs to charge 2 battery banks
  • Skylla-IP44 (3): three full current outputs to charge 3 battery banks
  • LCD display
  • CAN bus interface (NMEA2000)
  • Synchronised parallel operation
  • The right amount of charge for a lead-acid battery: variable absorption time
  • Preventing damage due to excessive gassing: the BatterySafe mode
  • Less maintenance and aging when the battery is not in use: the Storage mode
  • To increase battery life: temperature compensation
  • Battery voltage sense
  • Use as a power supply
  • Li-Ion (LiFePO4) ready

Skylla-IP44 Battery Charger

Product Overview

Skylla-IP44 Battery Charger 

12V/60A and 24V/30A, input voltage range 90-265V 

The Skylla-IP44 (1+1) features 2 isolated outputs. The second output, limited to approximately 3A and with a slightly lower output voltage, is intended to top up a starter battery.

The Skylla-IP44 (3) features 3 isolated outputs. All outputs can supply the full rated output current

Models: 12V/60A & 24V/30A

Skylla-IP44 (1+1): two outputs to charge 2 battery banks   The Skylla-IP44 (1+1) features 2 isolated outputs. The second output, limited to approximately 3A and with a slightly lower output voltage, is intended to top up a starter battery.

Skylla-IP44 (3): three full current outputs to charge 3 battery banks   The Skylla-IP44 (3) features 3 isolated outputs. All outputs can supply the full rated output current.

IP44 protection   Steel epoxy powder coated case and splash proof. Withstands the rigors of an adverse environment: heat, humidity and salt air. Circuit boards are protected with an acrylic coating for maximum corrosion resistance. Temperature sensors ensure that power components will always operate within specified limits, if needed by automatic reduction of output current under extreme environmental conditions.

LCD display   For status monitoring and to easily adapt the charge algorithm to a particular battery and its conditions of use.

CAN bus interface (NMEA2000)   To connect to a CAN bus network, to a Skylla-i Control panel or to the Color Control digital display.

Synchronised parallel operation   Several chargers can be connected in parallel and synchronised with help of the CAN bus interface. This is achieved by simply interconnecting the chargers with RJ45 UTP-cables.

The right amount of charge for a lead-acid battery: variable absorption time  When only shallow discharges occur the absorption time is kept short in order to prevent overcharging of the battery. After a deep discharge the absorption time is automatically increased to make sure that the battery is completely recharged

Preventing damage due to excessive gassing: the BatterySafe mode   If, in order to quickly charge a battery, a high charge current in combination with a high absorption voltage has been chosen, the Skylla-IP44 will prevent damage due to excessive gassing by automatically limiting the rate of voltage increase once the gassing voltage has been reached.

Less maintenance and aging when the battery is not in use: the Storage mode  The Storage mode kicks in whenever the battery has not been subjected to discharge during 24 hours. In the storage mode float voltage is reduced to 2,2V/cell (26,4V for 24V battery) to minimise gassing and corrosion of the positive plates. Once a week the voltage is raised back to the absorption level to ‘refresh’ the battery. This feature prevents stratification of the electrolyte and sulphation, a major cause of early battery failure.

To increase battery life: temperature compensation   Every Skylla-IP44 comes with a battery temperature sensor. When connected, charge voltage will automatically decrease with increasing battery temperature. This feature is especially recommended for sealed lead-acid batteries and/or when important fluctuations of battery temperature are expected.

Battery voltage sense   In order to compensate for voltage loss due to cable resistance, the Skylla-IP44 is provided with a voltage sense facility so that the battery always receives the correct charge voltage.

Use as a power supply   As a result of the excellent control circuit, the Skylla-IP44 can be used as a power supply with perfectly stabilized output voltage if batteries or large buffer capacitors are not available.

Li-Ion (LiFePO4) ready    Simple charger on-off control can be implemented by connecting a relay or open collector opto coupler output from a Li-Ion BMS to the remote control port of the charger. Alternatively complete control of voltage and current can be achieved by connecting to the CAN bus port.

Specifications

GENERAL
Output voltage

See selection table

Input voltage

90-265Vac

Frequency

45-65 Hz

Max AC input current

10A (at 100Vac input)

Power factor

0,98

Charge algorithm

7 stage adaptive

Charge algorithm, Li-Ion

3 stage, with on-off control or CAN bus control

Temperature sensor

Yes

Can be used as power supply

Yes

Remote on-off port

Yes (can be connected to a Li-Ion BMS)

CAN bus communication port

(VE.Can)

Two RJ45 connectors, NMEA2000 protocol, not isolated

Synchronised parallel operation

Yes, with VE.Can

Alarm relay

DPST AC rating: 240VAC/4A

DC rating: 4A up to 35VDC,

1A up to 60VDC

PROTECTION

Short circuit

Yes. output short circuit protection
Battery connection Yes, battery reverse polarity detection

Over temperature

Yes, temperature too high protection
STANDARDS
Safety EN60335-1, EN60335-2-29.
Emission 

EN 55014-1, EN 61000-6-3

EN 61000-3-2

Immunity

EN 55014-2, EN 61000-6-1,

EN 61000-6-2, EN 61000-3-3

ENVIRONMENTAL
Operating temperature

-20°C to 60°C.

Full load up to 40C ambient,

Forced cooling

Yes (internal air circulation)

Humidity 95% max (non condensing).
MECHANICAL
Material & Colour aluminium (blue RAL 5012)
Battery-connection M6 bolts
230 VAC-connection screw-clamp 6mm² (AWG 10)
Protection category IP44
Weight 6 kg
Dimensions hxwxd 401 x 375 x 265 mm

Selection Table

Skylla-IP44        

12/60 (1+1)

12/60 (3)

24/30 (1+1)

24/30 (3)

Charge voltage 'absorption'

  14,4 V 14,4 V 28,8 V 28,8 V

Charge voltage 'float'

  13,8 V 13,8 V 27,6 V 27,6 V

Charge voltage 'storage'

  13,2 V 13,2 V 26,4 V 26,4 V

Charge current, up to 40°C

Output reduces to 80% at 50°C,

and to 60% at 60°C.

  60 A

3 x 60A

(max total output: 60A)

30 A

3 x 30A

(max total output: 30A)

Charge current starter batt.

  3 A n. a. 3 A n. a.

Battery capacity

  300-600 Ah 300-600 Ah 150-300 Ah 150-300 Ah

Technical Illustration

Back to Top

Ask Your Question