Product Quick Selection Wheel

SKYLLA TG SERIES SKYLLA TG - Three Step Battery Charger

Features
  • 720W - 2400W
  • 24V and 48V Systems
  • Three Step Charger
  • Temp Compensation
  • On 24V models 2 separate outputs
  • Charge 2 battery banks
  • Corrosion Resistant

SKYLLA TG - Three Step Battery Charger

Product Overview

Skylla TG Battery Charger 

Skylla-TG ChargerOne full rated output and one 4 Amp output. Charge voltage can be precisely adjusted to suit any battery system. The input for the charger is 230V at 50/60HZ. Charge voltage can be measured directly on the battery terminals in order to compensate for voltage loss due to cable resistance. An external sensor allows measuring battery temperature and compensating charge voltage accordingly. Models: 24 / 48 Volt

Perfect chargers for any type of batteryCharge voltage can be precisely adjusted to suit any sealed or unsealed battery system. In particular, sealed maintenance free batteries must be charged correctly in order to ensure a long service life. Overvoltage will result in excessive gassing and venting of a sealed battery. The battery will dry out and fail.

Suitable for AC and DC supply (AC-DC and DC-DC operation) Except for the 3 phase input models, the chargers also accept a DC supply.

Controlled charging Every TG charger has a microprocessor, which accurately controls the charging in three steps. The charging process takes place in accordance with the IUoUo characteristic and charges more rapidly than other processes.

Use of TG chargers as a power supply As a result of the perfectly stabilized output voltage, a TG charger can be used as a power supply if batteries or large buffer capacitors are not available.

Two outputs to charge 2 battery banks (24V models only) The TG chargers feature 2 isolated outputs. The second output, limited to approximately 4 A and with a slightly lower output voltage, is intended to top up a starter battery.

To increase battery life: temperature compensationEvery Skylla TG charger comes with a battery temperature sensor. When connected, charge voltage will automatically decrease with increasing battery temperature. This feature is especially recommended for sealed batteries which otherwise might be overcharged and dry out due to venting.

Battery voltage sense In order to compensate for voltage loss due to cable resistance, TG chargers are provided with a voltage sense facility so that the battery always receives the correct charge voltage.

Specifications

INPUT
Input voltage

1ph: 185-264Vac, 3ph: 320-450Vac

180-400Vdc

Input frequency 45 - 65Hz
Power factor 1.0
BATTERY CHARGING OUTPUT
Battery Charging Optimum absorption charge and float charge voltages for Flooded Lead-acid, Gel-Cell or AGM batteries. Selectable by dip switch

Absorption

Charge voltage

28.5Vdc and 57Vdc

See selection table

Float

Charge voltage

26.5Vdc and 53Vdc

See selection table

Two Outputs

Two outputs to charge 2 battery banks (24V models only). The TG chargers feature 2 isolated outputs. The second output is limited to approx 4A and with a slightly lower output voltage. It is intended to top up a starter battery

See selection table

Total output ammeter Yes.
Charge characteristic Accurately controls the charging in 3 steps. Charges more rapidly than other processes
Temperature sensor Battery temperature sensor supplied. When connected charge voltage will automatically decrease with increasing battery temperature.
Battery Monitor

The BMV 600S battery monitor features an advanced control and measuring system for battery voltage and charge/discharge current. The battery monitor selectively displays battery voltage, current, consumed AH or time to go

Skylla Control

The Skylla Control allows you to alter the charge current and see the system status

Charger switch

A remote on-off switch

Remote alarm

Potential free contacts 60V / 1A (1 x NO & 1 x NC)

PROTECTION

Short circuit

Yes. output short circuit protection
Battery connection Yes, battery reverse polarity detection

Battery voltage

Yes, battery voltage too high

Over temperature

Yes, temperature too high protection
STANDARDS AND APPROVALS
Safety EN60335-1, EN60335-2-29.
Emission  EN55014, EN61000-3-2
Immunity EN55014-2, EN61000-3-3
C-tick AS/NZS CISPR11: Group 1, Class A.
ENVIRONMENTAL
Operating temperature -20°C to 60°C.
Derating Full load up to 40C ambient, Output will reduce to approximately 80% of nominal at 50C and 60% of nominal at 60C
Cooling Temperature and current controlled fan.
Humidity 95% max (non condensing).
MECHANICAL
AC connection Screw-clamp 2-5mm² (AWG 6)
Battery connection M8 studs
Protection category IP21.
Material & colour Aluminum epoxy powder coated cases (blue RAL 5012), Stainless steel fixings
Size & Weight

24/30TG-24/50TG: 365x250x147mm, 5.5Kg

24/50TG 3Phase: 365x250x257mm, 13Kg

24/80TG: 365x250x257mm, 10Kg

24/100TG: 365x250x257mm, 10Kg

24/100TG 3Phase: 515x260x265mm, 23Kg

48/25TG: 365x250x147mm, 5.5Kg

48/50TG: 365x250x257mm, 10Kg

Selection Table

MODEL DESCRIPTION

ABSORPTION 

CHARGE

VOLTAGE

FLOAT

CHARGE

VOLTAGE

OUTPUT

CURRENT

BATTERY

CONNECTION

RECOMMENDED

BATTERY SIZE

Skylla-TG 24/30(1+1) 230V 28.5V 26.5V 30A M8 Studs 150-500Ah
Skylla-TG 24/50(1+1) 230V 28.5V 26.5V  50A M8 Studs  150-500Ah
Skylla-TG 24/50(1+1) 3-Phase 400V 28.5V 26.5V 50A  M8 Studs  250-500Ah 
Skylla-TG 24/80(1+1) 230V 28.5V 26.5V 80A  M8 Studs  400-800Ah 
Skylla-TG 24/100(1+1) 230V 28.5V 26.5V 100A  M8 Studs  500-1000Ah 
Skylla TG 24/100 3-Phase 28.55V 26.5V 100A  M8 Studs  500-1000Ah 
Skylla-TG 48/25(1) 230V 57V 53V 25A  M8 Studs  125-250Ah 
Skylla-TG 48/50(1) 230V 57V  53V 50A  M8 Studs  250-500Ah 

Technical Illustration

Back to Top

Ask Your Question