Product Quick Selection Wheel

180...220W DC/AC Sine Wave Inverter PREMIUM OCS-260

Features
  • Sine wave output voltage
  • Selectable output frequency: 50/60Hz
  • Adjustable output voltage
  • Output failure alarm
  • Remote inhibit
  • High input-output isolation 3000Vrms
  • Optional railway version EN50155
  • Fire and smoke: EN45545-2 approved

PREMIUM OCS-260

Product Overview

The OCS-260 consists of sine-wave 120Vac or 230Vac output voltage DC-AC converters. The frequency can be set to 50Hzor 60 Hz, and input and output are galvanically isolated.

The OCS-260 inverters consist of two cascaded converters, one DC-DC generating an intermediate output voltage from the input voltage. That intermediate voltage is inverted to supply the output voltage and frequency by means of a second DC/AC converter.

The input is protected against reverse polarity by means of fuse and against under-voltage by unit shutdown.

The output has protection of maximum average power and maximum peak current. The unit shutdowns when the operation curve limit is exceeded for more than one second. Every 2 seconds after shutdown, the unit tries to restart up to 3 times. If the overload persists, the unit remains shutdown until an input reconnection.

Specifications

INPUT
Voltage See selection table
Max input ripple 5% Vin nom (Vrms, 100Hz) 
OUTPUT
Output Voltage See selection table.

Adjust range

± 5% of Vonom

Load regulation

4%

Line regulation

0.4% @ ΔVin -20…+25%

10% @ ΔVin -30…+25%

1% @ ΔVin -10…+25% for 12V input models

10% @ ΔVin -20…+25% for 12V input models

Output frequency

50 / 60Hz ± 0.25Hz

Output wave distortion THD

< 2% (16 samples average)

Output voltage HF ripple

< 20Vpp for 230Vac models < 10Vpp for 120Vac models

ENVIRONMENTAL

StorageTemperature

-40°C ... 80°C

Operating temperature at Full load -40 ... 55°C
Operating temperature at 62.5% load -40 ... 70°C
Cooling  Natural convection 
MTBF (MIL-HDBK-217-E; Gb, 25°C) 250.000 h
EMC

Immunity according 

EN61000-6-2 EN50121-3-2

Emissions according 

EN61000-6-3 EN50121-3-2

SAFETY

Safety according to

EN60950-1, EN62368-1

Class I OV category II, Pollution degree 2

Input / output isolation: reinforced 

Dielectric strength Input/Output

3000 Vrms / 50Hz / 1min (routine test 2s)

Dielectric strength Input / Ground

1500 Vrms / 50Hz / 1min (routine test 2s) 

Dielectric strength Output / Ground

500 Vrms / 50Hz / 1min (routine test 2s) 

Fire and smoke

EN45545-2 

MECHANICAL

Approximate weight

900g

Dimensions

100 x 220 x 40mm

CONTROL

Remote inhibit input

4 ... 24Vdc 

Output failure alarm

Solid state relay, open when alarm. Max: 60V, 0.3A 

PROTECTIONS

Against Input over-currents

Internal fuse 

Against output overloads < Iompk

linear

Against output overloads > Iompk 

Triggered 

Selection Table

PART NUMBER

INPUT

VOLTAGE

DC

(V)

INPUT

VOLTAGE

RANGE

(V)

MAX

INPUT

CURRENT 

(A)

OUTPUT

VOLTAGE

AC

(V)

OUTPUT

CURRENT 

(A) 

ACTIVE

OUTPUT

POWER

(W)

APPAR.

OUTPUT

POWER

(VA)

OUTPUT

PEAK

CURR. 10MS 

(A)

EFFICIENCY

(%)

NO LOAD

INPUT

CURRENT

(A)

OCS-260-7031

12 9.50 - 15 22.1 230 0.78 180

260

4.0

86

0.50

OCS-260-7033

24 16.8 - 30 13.7 230 0.87 200

260

4.0

87

0.36

OCS-260-7034

36 25.0 - 45 10.0 230 0.96 220

260

4.0

88

0.21

OCS-260-7035

48 33.6 - 60 7.36 230 0.96 220

260

4.0

88

0.15

OCS-260-7036

72 50.4 - 90 4.91 230 0.96 220

260

4.0

89

0.11

OCS-260-7037

110 77 - 138 3.17 230 0.96 220

260

4.0

90

0.08

OCS-260-7041

12 9.50 - 15 22.3 120 1.50 180

260

7.6

85

0.50

OCS-260-7043

24 16,8 - 30 13.7 120 1.67 200

260

7.6

87

0.26

OCS-260-7044

36 25.0 - 45 10.0 120 1.83 220

260

7.6

88

0.21

OCS-260-7045

48 33.6 - 60 7.45 120 1.83 220

260

7.6

88

0.15

OCS-260-7046

72 50.4 - 90 4.97 120 1.83 220

260

7.6

88

0.11

OCS-260-7047

110 77 - 138 3.22 120 1.83 220

260

7.6

89

0.08