Product Quick Selection Wheel

1300VA DC/AC INVERTER PREMIUM ODX-1300

Features
  • Sine wave output voltage
  • Suitable for motors control
  • Adjustable output voltage
  • High input-output isolation 3000Vrms
  • Remote control via RS232
  • Alarm by isolated relay contacts
  • Remote ON/OFF opto-coupled
  • According to the standard EN50155
  • Fire and smoke: EN45545-2 approved

PREMIUM ODX-1300

Product Overview

The ODX-1300 consists of three phase sine-wave DC-AC inverters with galvanic isolation between input and output. The unit allows:

  • Start-up motors by means of a soft start. In the startup, the output voltage and frequency rise linearly from 0V to set voltage and from 5Hz to set frequency. The start-up ramp slope may be changed via RS-232 port
  • Set the rotation speed of a motor according to the appropriate Voltage/Frequency ratio. Monitoring the status of the input and output. Set and monitor parameters via RS-232.
  • The ODX-1300 has a maximum output current protection. This protects the semiconductors even when an output short-circuit occurs. It also features a disable function for input under-voltage.

Specifications

INPUT
Input voltage range -30, +25% Vin nom
Max input ripple 5% Vin nom (Vrms, 100Hz)
Inrush current <25A
Polarity protection By diode
OUTPUT
Nominal Output Voltage (Von) See selection table

Output voltage range

150 … 250V (models of 250V output) via RS-232

200 … 400V (models of 400V output) via RS-232

Output frequency range

5…60Hz via RS-232

Load regulation 

< 4%

Line regulation 

< 2% Vin -25% … +25%, < 10% Vin -30% … +30%

Output wave distortion THD

< 3% (average of 16 samples)

Output HF ripple

< 2.5%
ENVIRONMENTAL

StorageTemperature

-25 … 85°C

Operating temperature at Full load -25 … 55°C (EN50155 OT1)
Operating temperature at 62.5% load -25 … 70°C (EN50155 OT3)
Operating temperature at 25% load  -25 … 85°C (EN50155 OT5)
Relative humidity without condensation 5 … 95%
Cooling Controlled internal fan
MTBF (MIL-HDBK-217-E; Gb, 25°C)  100.000 h
EMC

Immunity according

EN61000-6-2, EN50121-3-2

Emissions according 

EN61000-6-4, EN50121-3-2

SAFETY

Dielectric strength: Input /output 

3000 Vrms / 50Hz / 1min

Dielectric strength: Output / ground

1500 Vrms / 50Hz / 1min

Dielectric strength: Input / ground

1500 Vrms / 50Hz / 1min

Safety according to

EN60950-1, EN62368-1

Fire and smoke

EN45545-2

MECHANICAL

Approximate weight

<3200g

CONTROL

Output  alarm

Open when alarm. Maximum rating: 0.16A at 160Vdc

Remote OFF input

Off applying 15…143Vdc, Impedance>18kΩ

PROTECTIONS

Against overloads and short-circuits

Shutdown with auto-recovery (see working parameters)

Against over-temperature

Shutdown with auto-recovery

Selection Table

MODEL

INPUT

VOLTAGE

DC

(V)

INPUT

VOLTAGE

RANGE

(V)

OUTPUT

VOLTAGE

AC

(V)

OUTPUT

CURRENT 

(A) 

ACTIVE

OUTPUT

POWER

(W)

APPAR.

OUTPUT

POWER

(VA)

OUTPUT

PEAK CURR.

10MS (Iopk) 

(A)

EFFICIENCY

(%)

NO LOAD

INPUT

CURRENT

(A)

SIZE

ODX-1300-7442

24 16.8 - 30 250 3.10 1100

1300

6.6

89

< 1.58 2

ODX-1300-7445

72 50.4 - 90 250 3.10 1100

1300

6.6

90

< 0.52 1

ODX-1300-7447

110 77 - 138 250 3.10 1100

1300

6.6

90

< 0.34 1

ODX-1300-7452

24 16.8 - 30 400 1.88 1100

1300

3.4

89

< 1.58 2

ODX-1300-7455

72 50.4 - 90 400 1.88 1100

1300

3.4

90

< 0.52 1

ODX-1300-7457

110 77 - 138 400 1.88 1100

1300

3.4

91

< 0.34 1

Technical Illustration

Back to Top

Ask Your Question