Product Quick Selection Wheel

CAMTEC - 480W Programmable DC Lab Power Supply, TS35mm DIN-Rail HSEUREG04801 SERIES

Features
  • 480W voltage 0-Vmax programmable laboratory power supply
  • Save 0–Umax programming
  • Multi interface 0-10V & 0-20mA
  • Sense & Shutdown (remote ON/OFF)
  • N+1 parallel operation
  • Natural Convection
  • Precise dynamic response on load change
  • Designed for long life under full stress
  • Strong input filters
  • High reliability
  • shock & vibration proof
  • EMC meets CE norm class B
  • Over Voltage and continuous short circuit protection

HSEUREG04801 SERIES

Product Overview

CAMTEC - HSEUREG04801 SERIES 

480W Programmable DC Lab Power Supply, TS35mm DIN-Rail  

Available Outputs:   0-15V,   0-30V,   0-50V,   0-90V,   0-130V,   0-180V,   0-240Vdc  

Description   The HSEUREG laboratory power supplies provide low noise and ripple, a very quick programming, and an absolutely precise setting at high load changes. With an efficiency up to 90% the devices are highly energy efficient. Equipped with high-end capacitors of outstanding lifetime our power supplies guarantee a very long and reliable operation time. The circuit design of the HSEUREG Series allows cope playing with complex loads. The internal protection circuits protect the power supply and the connected system, even in exceptional situations. The HSEUREG series is protected from high transients by strong filters with high energy efficiency. All inputs and outputs and the interface are electrically isolated. The design specifications call for the highest standards of safety and interference suppression. The device was developed in accordance with the requirements of IEC/CSA/UL60950-1 and the EMC standards EN55022 Class B. The 480W and 720W models provide natural convection. The 1kW models use a forced air cooling system with a two stages fan

Design Conception   The HSEUREG power supply series realizes high programmable power in a space-saving housing. Latest generation electrical devices relate to the high reliability of all CAMTEC products. The CAMTEC philosophy is, to employ 125°C low ESR ultra long life capacitors where expedient to achieve a superior lifetime of the product. The HSEUREG power supply is made for high reliable and demanding industrial applications like galvanic systems, professional DC-drives, and complex test benches

Control type   The power supplies accurately works down low output voltages down to 0V. Thereby the switching frequency is absolute stabile. The output response is linear to the input signal.

Power Good Relay:   As a standard the power good relay allows to control the power supply is ok. When the output voltage breaks down the contact opens. Galvanic isolation 60vdc..

Programming Performance   THE HSEUREG power supply is very equal to a typical laboratory power supply – just without its displays. It is designed for automated industrial test benches in a 24/7 operation. The HSEUREG provides save and precise down to zero voltage programming. The product is equipped with a multi-functional interface. Thus the interface can be operated with either 0- 10Vdc/20mA or with 0-20mA programming. The burden is 500Ω to ensure interference free operation with high impedance controller interfaces. The device features a small latency and a quick all rise time that leads to typical 15ms from zero to Umax programming.

Galvanic Isolation   The power supply is galvanic isolated between the input and the output. All features like the Power Good Relay are connected to the DC power outputs.

Thermal shutdown   The HSEUREG is featured with a thermal overload shut down and auto recovery behaviour.

Over Voltage Protection   Ticker mode and auto recovery

Short Circuit Protection   A continuous short circuit does not cause damage to the power supply. The HSEUREG delivers constant current and zero output voltage. It recovers automatically after the short circuit is released.

Open Circuit Protection   The HSEUREG series is continuously open circuit protected. The device delivers a stable output voltage and no current. If a load is immediately connected to the device, the power supply stabilizes within 1ms. It does not overshoot the output voltage.

Power Up Ramp   The devices has a soft start ramp when powering up. The device does not either overshoot the voltage nor does the output flutter – independent if a load is connected or not.

Specifications

GENERAL
Output Voltage See selection table
AC Input Voltage 90..132Vac / 184..265Vac
Frequency 47-63Hz
DC Input Voltage 250…375Vdc
Input Rating

115Vac<8.8A , 230Vac<4.3A

250Vdc<2.4A 375Vdc<1.6A

DC Input Voltage 250…375Vdc
Sense function Compensation 2V per lead load, protective electrical separation ≤60Vdc
Remote Shutdown Protective electrical separation ≤60Vdc
Analogue Interface see table, protective electrical separation ≤60Vdc, working impedance = 500Ω
Pmax (average) 480W continuous and ca. 528-540W bower boost for max. 60s (see Power Boost above)
Derating +60°C...+70°C 2.5%/°C
Accuracy < ± 1.5% Interface
Latency Interface 15ms including signal latency for 0-Umax programming
Load regulation < ± 0.2% 0-100%
Response Load Change <1ms 10-100%, 100-10%
Base Load None
Base Load None
Efficiency 230Vac 90% typical
Short Circuit Protection Continuous
Idling-proof Yes
Temperature Control Yes, thermal shutdown with auto recovery (+70°C, metering distance 10mm)
Hold Up Time > 50ms 230Vac
Inrush Current < 81A (230Vac) @25°C
MCB (Miniature Circuit Breaker) 16A curve B (need to connect 2-3 units to a single 16A MCB? use our ESB101.33 limiter!)
Soft Start 100ms typical
Isolation Path > 8mm
Input / Output Galvanic insulated
Meantime By Failure (MTBF) 400000h (IEC61709)
ENVIRONMENTAL
Cooling Natural convection
Ambient Operating Temp. - 25°C…+70°C
Ambient Storage Temp. - 40°C…+85°C
Environment Environment Humidity 95% non-condensing @ 25°C, climate class. 3k3, pollution rate II
STANDARDS AND APPROVALS
REACH EG No. 1907/2006 confirmed
EMI EN55022 class B
EMS EN61000-6-2,3
Safety EN60950-1, EN60204-1
Safety class 1(A) VDE0805, VDE0100
ROHS 2011/65/EG confirmed
MECHANICAL
Dimensions (HxWxD) 130x200x114,5mm
Weight 2900g
Screw Terminals (In/Out) AWG20...AWG6 , 0.5...16mm² (76A @ 40°C)

Selection Table

MODELHSEUREG04801.015THSEUREG04801.030THSEUREG04801.050T
Rated DC Voltage 0-15V 0-30V 0-50V
Overvoltage Protection 18Vdc 35Vdc 59Vdc
Rated DC Current 26.0A 16.0A 10.0A

Power Boost

-25...+60°C <1min.

28.6A 17.6A 11.0A
Max. DC Current +70°C 19.5A 12.0A 7.5A
Ripple Peak 230Vac 20MHz 40mVpp 50mVpp 100mVpp
MODEL HSEUREG04801.090T HSEUREG04801.130T HSEUREG04801.180T
Rated DC Voltage 0-90V 0-130V 0-180V
Overvoltage Protection 105Vdc 150Vdc 210Vdc
Rated DC Current 5.3A 3.7A 2.7A

Power Boost

-25...+60°C <1min.

5.8A 4.1A 3.0A
Max. DC Current +70°C 4.0A 2.8A 2.0A
Ripple Peak 230Vac 20MHz 150mVpp 200mVpp 300mVpp
Options
Screw Terminal Plug

Optional Plug for the interface, 2 poles LS5,08 180°cabling,

ADTW201

Optional DC-repeater 1:1 with no losses for save interface separation >60Vdc

Protective Coating

Ask for technical support and quotation

 

Technical Illustration

  • Programming Time Vout [ms] Programming Time Vout [ms]
  • Analog Interface Analog Interface
  • Programming Interface Ureg Programming Interface Ureg
  • Block Diagram Block Diagram
  • Mechanical Mechanical
Back to Top

Ask Your Question