SM6000 SERIES SM6000 - Laboratory Power Supply

Features
  • 6000W Laboratory Supply
  • Ranges 0-15V to 0-600V and 0-10A to 0-400A
  • Designed for long life at full power
  • Excellent dynamic response to load changes
  • Protected against all overload and short circuit conditions
  • EMC surpasses CE requirements for low emissions and high immunity
  • Low audible noise - fans are temperature controlled
  • Master/Slave parallel and series operation with voltage and current sharing
  • High power system configuration from multiple units
  • 19" rack mounting for for laboratory use (feet included)
  • Stacking is allowed & space between units is not required

SM6000 - Laboratory Power Supply

Product Overview

Delta Elektronika SM6000 Series

The Delta Elektronika range of Laboratory Power Supplies have been designed to meet the challenges of today's demanding equipment. Delta has been designing and producing power supplies and has become a leader in a market that demands efficiency and reliability. Delta laboratory power supply units undergo rigorous thermal soaking tests before being dispatched to the customer. This ensures the long term correct functioning of each unit and client satisfaction.

Delta Elektronika's SM6000 Series, 6000W 19"-rack or bench power supply, low noise, accurate and very stable outputs. Built in programming via Ethernet and possibilities of download sequences and settings from USB. The unit has a low noise temperature regulated fan cooling. 4U high and stackable permits compact high power designs. 3 phase input. RS232, GPIB, IEEE488, PROFIBUS och CAN open interface.

Specifications

INPUT
Input voltages 342 - 528Vac  3Ph
Input Frequency 48 - 62Hz
Power Factor

400V 3Ph, full load

0.98, with 100% load

0.97 with 50% load

Input Current

10.2A rms (400Vac 3ph)

Internal Fuse

15 AT

Standby input power

55W Vo = 0

110W Vo = max

Turn on delay

200ms (after mains switch on

Inrush Current

20A (electronic limit)

Phase Loss

Output shuts down in case of phase loss

Hold-up time

6ms 100% load Vin=3x380Vac

15ms 50% load Vin=3x380Vac

OUTPUT
Output Voltage Range

0-15V to 0-600V

Auto ranging models

See Selection Table

Output Current Range

0-10A to 0-400A

Auto ranging models

See Selection Table

Output Power Range

0 to 6000W

See Selection Table

ANALOG PROGRAMMING
Programming Inputs: CV

Input Range: 0 - 5V

Accuracy: +/-0.2%

Offset: -0.1...+1.3mV (on 5V)

Temp. coeff. offset:: 10uV/C

Input Impedance: > 1Mohm

Programming Inputs: CC

Input Range: 0 - 5V

Accuracy: +/-0.5%

Offset: 0...+2.2mV (on 5V)

Temp. coeff. offset:: 50uV/C

Input Impedance: > 1Mohm

Monitoring Outputs: CV

Input Range: 0 - 5V

Accuracy: +/-0.2%

Offset: -1.1..0mV (on 5V)

Temp. coeff. offset:: 3uV/C

Output Impedance: > 2 ohm /  max 4mA

Monitoring Outputs: CC

Input Range: 0 - 5V

Accuracy: +/-0.5%

Offset: -1.1..0mV (on 5V)

Temp. coeff. offset:: 60uV/C

Output Impedance: > 2 ohm /  max 4mA

Reference voltage

Vref: 5.114V +/-15mV (Ro = 2ohm, max 4mA)

TC: 20ppm

+12V output

Vo: 12V+/-0.23V

Imax: 0.2A

Ro: 3ohm

 

OPERATING
Series Operation

Max total voltage 600V

Master / Slave operation yes

Parallel Operation

Max total current - No limit

Master / Slave operation - max 3 units (including master)

Remote Sensing Max volt, drop per load lead: 2V
Potentiometers & Encoders

Standard: Front panel control with knobs

Resolution: 0.03%

Screwdriver adjustment

Option P001

Digital encoders

Option P002

Remote Shutdown

with +5V, 1mA or relay contact

Interlock

Contact at rear panel

Indicators Voltage meter, Amp meter, AC-Fail, DC-Fail, Over Temperature, Power Sink Overload, Remote Shutdown,, Remote-CV, Remote-CC, Output On,CV-limit, CV- and CC- mode
Controls Mains on/off switch, CV and VV potmeter, CV and CC limit potmeter, Display Settings button, Display limits button, Remote/Local button, Output On/off button, Front panel lock button
Efficiency 87% Typical
Isolation

Input - Output: 3750Vrms(1 min)

Creepage clearance; 8mm

Input - Case: 2500Vrms

Output - Case: 600VDC

MTBF 500,000hrs

 

STANDARDS AND APPROVALS
Safety

cTUVus / EN60950 / EN61010

Power Supply Standard

EN61204-3

Emission residential light industrial environment CISP22 Class B

Immunity - industrial environment

General Emission

EN61000-6-3 residential, light industrial environment EN55022B

EN61000-6-2, industrial environment

ENVIRONMENTAL
Operating Temperature

-20°C to +50°C (100% load)

Derate output to 75% at 60°C

Temperature coefficient 0.02%./°C
Storage temperature -40°C to 85°C.
Thermal Protection Output shuts down in case of insufficient cooling
Humidity

max 95% RH, non condensing up to 40°C

max 75% RH, non condensing up to 50°C

MECHANICAL
Mounting Stacking of units allowed, air flow is from left to right.
Input Connector

Screw terminals for cable 2.5 - 4.0mm2

3 phase + earth (no neutral required)

Output Terminals

0-15V: M12 bolts

0-30V, 0-45V, 0-60V,0-70V M10 bolts

0-120V, 0-300V, 0-600V; M8 bolts

Programming Connector 15 pole D-connector at rear panel (FEMALE)
Enclosure IP20 Protection
Dimensions

177x 443 x 500mm Behind front panel (feet removed)

177 x 483mm, Front panel (19" 4U)

Weight 27kg

Selection Table

 OUTPUTSM 15-400SM 30-200SM 45-140SM 60-100SM 70-90SM 120-50SM 300-20SM 600-10

Output Voltage Range

Output Current Range

0 - 15V

0 - 400A

0 - 30V

0 - 200A

0 - 45V

0 - 140A

0 - 60V

0 - 100A

0 - 70V

0 - 90A

0 - 120V

0 - 50A

0 - 300V

0-20A

0 - 600V

0-10A

Meters

Scale voltage

Scale current

Accuracy

3.5 digit

0 - 15.00 V

0 - 400 A

0.5% + 2 digit

3.5 digit

0 - 30.0 V

0 - 200.0 A

0.5% + 2 digit

3.5 digit

0 - 45.0 V

0 - 140.0 A

0.5% + 2 digit

3.5 digit

0 - 60.0 V

0 - 100.0 A

0.5% + 2 digit

3.5 digit

0 - 70.0 V

0 - 90.0 A

0.5% + 2 digit

3.5 digit

0 - 120 V

0 - 50.00 A

0.5% + 2 digit

3.5 digit

0 - 300 V

0 - 20.0A

0.5% + 2 digit

3.5 digit

0 - 600 V

0 - 10.0 A

0.5% + 2 digit

 

 

 

PROGRAMMING SPEED

STANDARD VERSION

(Resisitive Load)

SM 15-400

SM 30-200

SM 45-140

SM 60-100

SM 70-90

SM 120-50

SM 300-20

SM 600-10

Rise time (10 - 90%)

Output voltage step

Time, (100 % load)

Time, (10 % load)

 

0 - 15 V

7 ms

7 ms

 

0 - 30 V

7 ms

7 ms

 

0 - 45 V

7 ms

7 ms

 

0 - 70 V

7 ms

7 ms

 

0 - 120 V

7 ms

7 ms

 

0 - 300 V

7 ms

7 ms

   

Fall time (90 - 10%)

Output voltage step

Time, (100 % load)

Time, (10 % load)

 

15 - 0 V

7 ms

32 ms

 

30 - 0 V

7 ms

58 ms

 

45 - 0 V

87 ms

29 ms

 

70 - 0 V

8 ms

82 ms

 

120 - 0 V

7 ms

39 ms

 

300 - 0 V

11 ms

91 ms

   

Programming bandwidth

Small signal

Large signal,(100 % load)

Large signal,(10 % load)

 

50 Hz

50 Hz

5 Hz

 

50 Hz

50 Hz

5 Hz

 

50 Hz

50 Hz

5 Hz

 

50 Hz

50 Hz

5 Hz

 

50 Hz

50 Hz

5 Hz

 

50 Hz

50 Hz

5 Hz

   

Technical Illustration