Product Quick Selection Wheel

ORION-TR Isolated Series ORION-TR - Victron Isolated DC Converters

Features
  • 110W; 220W; 360W Isolated dc converter
  • Remote on-off
  • Adjustable output voltage
  • Can be used as a battery charger
  • Short circuit proof protection
  • Can be connected in parallel
  • IP43 protection
  • Screw terminals

ORION-TR  -  Victron Isolated DC Converters

Product Overview

 

Orion-Tr DC-DC converters isolated: 100Watt

Remote on-off: The Remote on-off connector eliminates the need for a high current switch in the input wiring.  The remote on-off can be operated with a low power switch or by the engine run/stop switch

Adjustable output voltage: can also be used as a battery charger.  For example to charge a 12 Volt starter or accessory battery in an otherwise 24V system.

All models are short circuit proof and can be paralleled to increase output current. An unlimited number of units can be connected in parallel.

The Orion have IP43 protection, when installed with screw terminals orientated downwards.

The input fuse (not replaceable) on 12V and 24V input models only. 


Specifications

INPUT
Input voltage

12V, (8 - 17V)

24V, (16 - 35V)

48V, (32 - 70V)

See selection table

OUTPUT
Output voltage

12.2Vdc,

24.2Vdc, 

48.2Vdc,

See selection table

Output voltage tolerance

+/- 0,2V 

Output noise

2mV rms 

Undervoltage shutdown

12V, 7Vdc

24V, 14Vdc

48V, 28Vdc

Undervoltage restart

12V, 7.5Vdc

24V, 15Vdc

48V, 30Vdc

Efficiency

Typically 87 - 89%

Galvanic Isolation

200V dc between input, output and case 

PROTECTION
Overcurrent

Short circuit proof

Over heating

Reduction of output voltage

Reverse Polarity

Fuse and reverse connected diode across input

Over voltage

Varistor (also protects against load dump)

MECHANICAL
Connections

Screw terminals 

Maximum cable

cross-section

100W:  6 mm²  AWG6 

220 - 360W:  13 mm²   AWG10 

Dimensions

(H x W x D)

 100W:  100 x 113 x 47mm  

220W:  130 x 186 x 70mm  

360W:  12V: 130 x 186 x 80mm  

360W:  24V, 48V: 130 x 186 x 70mm 

Weight

100W:  0,42 kg

220W:  1.3kg 

360W:  12V: 1.4kg

360W:  24V, 48V: 1.6kg

ENVIRONMENTAL
Operating Temperature

 -20 to +55°C

 (derate 3% per °C above 40°C) 

Humidity

 Max. 95%

non-condensing

STANDARDS AND APPROVALS
Safety EN60950
Emission  EN 61000-6-3, EN 55014-1 
Immunity EN 61000-6-2, EN 61000-6-1, EN 55014-2 
Automotive Directive ECE R10-4 

Selection Table

 

Isolated Converters

110-120W

Orion-Tr

12/12-9  

(110W) 

Orion-Tr

12/24-5

(120W)

Orion-Tr

24/12-9

(110W) 

Orion-Tr

24/24-5

(120W) 

 Orion-Tr

24/48-2,5

(120W) 

Orion-Tr

48/12-9  

(110W) 

Orion-Tr

48/24-5

(120W)  

Orion-Tr

48/48-2,5

(120W) 

Input voltage range 8-17V

8-17V

16-35V  16-35V  16-35V  32-70V  32-70V 32-70V
Under voltage shut down 7V 7V 14V  14V  14V  28V  28V 28V
Under voltage restart 7,5V 7,5V 15V  15V  15V  30V  30V 30V
Nominal output voltage 12,2V  24,2V 12,2V  24,2V  48,2V  12,2V  24,2V 48,2V
Output voltage adjust range 10-15V 20-30V 10-15V  20-30V  40-60V  10-15V  20-30V  40-60V
Cont. output current at 25°C 9A

5A

9A  5A  2.5A  9A  5A 2.5A
Maximum output current  12.5A 6.3A 12.5A  6.3A  3.0A  12.5A  6.3A 3.0A
Short circuit output current  32A  23A  39A  30A  19A  27A  25A  17A 
Cont. output power at 25°C  110W  120W  110W  120W  120W  110W  120W  120W 
Cont. output power at 40°C  85W  110W  85W  115W  115W  85W  100W  85W 
Off load current  < 50mA  < 80mA  < 40mA  < 60 mA  < 120mA  < 50mA  < 60mA  < 80mA

 

Isolated Converters

220-280W

Orion-Tr

12/12-18  

(220W) 

Orion-Tr

12/24-10

(240W)

Orion-Tr

24/12-20

(240W) 

Orion-Tr

24/24-12

(280W) 

 Orion-Tr

24/48-6

(280W) 

Orion-Tr

48/12-20  

(240W) 

Orion-Tr

48/24-12

(280W)  

Orion-Tr

48/48-6

(280W) 

Input voltage range 8-17V

8-17V

16-35V  16-35V  16-35V  32-70V  32-70V 32-70V
Under voltage shut down 7V 7V 14V  14V  14V  28V  28V 28V
Under voltage restart 7,5V 7,5V 15V  15V  15V  30V  30V 30V
Nominal output voltage 12,2V  24,2V 12,2V  24,2V  48,2V  12,2V  24,2V 48,2V
Output voltage adjust range 10-15V 20-30V 10-15V  20-30V  40-60V  10-15V  20-30V  40-60V
Cont. output current at 25°C 18A

10A

20A  12A  6A  20A  12A 6A
Maximum output current  25A 15A 25A  15A  8A  25A  15A 8A
Short circuit output current 40A  25A  50A  30A  25A  50A  30A  25A 
Cont. output power at 25°C  280W  280W  300W  320W  320W  280W  320W  320W 
Cont. output power at 40°C  220W  240W  270W  280W  280W  240W  280W  280W 
Off load current  < 80mA  < 100mA  < 100mA  < 80 mA  < 120mA  < 80mA  < 80mA  < 80mA

 

Isolated Converters

360 - 400 Watt

Orion-Tr

12/12-30

(360W) 

Orion-Tr

12/24-15

(360W) 

Orion-Tr

24/12-30

(360W) 

Orion-Tr

24/24-17

(400W) 

Orion-Tr

24/48-8,5

(400W) 

Orion-Tr

48/12-30 

(360W) 

Orion-Tr

48/24-16

(380W)

Orion-Tr

48/48-8

(380W)

Input voltage range 10-17V

10-17V

20-35V  20-35V  20-35V  40-70V  40-70V 40-70V
Under voltage shut down 7V 7V 14V  14V  14V  28V  28V 28V
Under voltage restart 7,5V 7,5V 15V  15V  15V  30V  30V 30V
Nominal output voltage 12,2V  24,2V 12,2V  24,2V  48,2V  12,2V  24,2V 48,2V
Output voltage adjust range 10-15V 20-30V 10-15V  20-30V  40-60V  10-15V  20-30V  40-60V
Cont. output current at 25°C 30A

15A

30A  17A  8.5A  30A  16A 8A
Maximum output current  40A 25A 45A  25A  15A  40A  25A 15A
Short circuit output current 60A  40A  60A  40A  25A  60A  40A  25A 
Cont. output power at 25°C  430W 430W  430W  480W  480W  480W  430W  430W 
Cont. output power at 40°C  360W  360W  360W  400W 400W  360W  380W  380W 
Off load current  < 80mA  < 100mA  < 100mA  < 80 mA  < 120mA  < 80mA  < 80mA  < 80mA
Back to Top