INPUT
18-36V
|
OUTPUT
AMPS
| |
INPUT
36-75V
|
INPUT
45-90V
|
INPUT
80-160V
|
INPUT
160 – 320V
|
INPUT
320 – 380 V
|
INPUT
320 – 640V
|
OUTPUT
AMPS
| |
COOLING
| |
OUTPUT
VDC
|
OUTPUT
RANGE
|
C3720 |
120(2) |
|
C3730 |
C3740 |
C3750 |
C3770 |
C3780Z |
C3770G |
150 |
|
F |
|
5 |
4.5 – 5.5 |
C3721 |
80 |
|
C3731 |
C3741 |
C3751 |
C3771 |
C3781Z |
C3771G |
100 |
|
H |
|
9 |
8 – 10 |
C3722 |
70 |
|
C3732 |
C3742 |
C3752 |
C3772 |
C3782Z |
C3772G |
85 |
|
H |
|
12 |
11 – 13 |
C3723 |
56 |
|
C3733 |
C3743 |
C3753 |
C3773 |
C3783Z |
C3773G |
70 |
|
H |
|
15 |
14 – 16 |
C3724 |
40 |
|
C3734 |
C3744 |
C3754 |
C3774 |
C3784Z |
C3774G |
50 |
|
H |
|
24 |
23 – 26 |
C3725 |
35 |
|
C3735 |
C3745 |
C3755 |
C3775 |
C3785Z |
C3775G |
42 |
|
H |
|
28 |
26 – 30 |
C3729 |
19 |
|
C3739 |
C3749 |
C3759 |
C3779 |
C3789Z |
C3779G |
23 |
|
H |
|
48 |
45 – 55 |
C3726 |
15 |
|
C3736 |
C3746 |
C3756 |
C3776 |
C3786Z |
C3776G |
18 |
|
H |
|
60 |
58 – 68 |
C3727 |
8 |
|
C3737 |
C3747 |
C3757 |
C3777 |
C3787Z |
C3777G |
10 |
|
H |
|
110 |
100 – 130 |
C3727J |
5 |
|
C3737J |
C3747J |
C3757J |
C3777J |
C3787ZJ |
C3777GJ |
6 |
|
H |
|
200 |
190 – 200 |
C3728 |
4 |
|
C3738 |
C3748 |
C3758 |
C3778 |
C3788Z |
C3778G |
5 |
|
H |
|
220 |
200 – 250 |
C3728J |
2.5 |
|
C3738J |
C3748J |
C3758J |
C3778J |
C3788ZJ |
C3778GJ |
3 |
|
H |
|
400 |
380 – 400 |
Cooling
H: Heatsink - natural convection
F: Fan - increased airflow recommended
TF: Temperature controlled Fan included
See selection table
|
Model configuration options:
|
Add the options to the model number, eg. C3674-dd-dr-cs
Options for Input, Output, Environmental and Mechanical follow.
|
19" Rack Mounting Options |
Subrack Height 3U, 5U, 6U
Wiring, Front Panels
Accessories: Fuses, MCBs, Mains on/off switch
Contact Powerbox for rack configuration
|
OPTIONS
INPUT |
Option “i” |
(inrush current limiting): A thermistor is connected in series with the
input lines which changes its resistance from high to low when it gets hot. It does
not reduce the current surge if the input power is interrupted for a short period of
time not allowing the thermistor to cool down. Thermistors are fitted as standard
to all mains input models except for 1-phase input of models > 2.5kW.
Thermistors are available up to 45A. For higher input current an electronic inrush
current limitation can be offered. |
---|
Option “ie” |
electronic inrush current limiting An electronic circuit limits the inrush
current. |
---|
Option “sd” |
(series diode): A series diode protects the module against input
voltage of wrong polarity (additional power losses). |
---|
Option “ad” |
(anti-parallel diode): To avoid the power losses of a series diode a diode is
provided with opposite polarity in parallel to the input blowing an internal or external
fuse if the module is connected to a supply with wrong polarity. |
---|
Option “au” |
(auto-ranging) For standard dual AC input models the range of
115/230Vac is to be selected by connecting the input line to different pins on the
connector. With auto-ranging the unit senses the input voltage and provides
automatically the correct connection. |
---|
Option “p” |
(power fail): A signal (logic or relay) is given if the input voltage (AC or
DC) drops below the specified limit. In AC input units we sense the rectified input
voltage so that a power fail alarm will not be triggered if at light loads mains
power returns before the input capacitors are substantially discharged. |
---|
Option “r” |
(relay): A relay instead of a logic signal is provided for failure indication. |
output |
Option “dd” |
(decoupling diode): For redundant operation the outputs of two or
more units are paralleled behind de-coupling diodes so that an internal fault of
one module does not affect the operation of the others. These diodes cause power
losses. |
---|
Option “cs” |
(active current sharing): An additional control circuit provides active
current sharing via an interconnecting wire between converters that operate in
parallel. Active current sharing should be used for multi-output units operating in
parallel.
|
---|
Option “csi” |
(current sharing interrupt): Option "csi" will effect the removal of the
"cs" signal. Should there be an instance where a unit is not supplying the load,
then the effect of its "cs" signal is removed, and the load voltage is unaffected by
this condition. |
---|
Option “h1” |
(inhibit): A terminal connected to the negative input line also shuts off the
converter. This can also be used in conjunction with a thermal trip which shuts the unit
down. |
---|
Option “h2” |
(inhibit): Operation of the unit is inhibited if a voltage signal
(5V/10mA) is applied in reference to the negative line of the (main) output. |
---|
Option “rco” |
(reducing current limiting at over temperature) A circuit reduces the
current limiting level at higher temperature (to be specified). |
---|
Option “d” |
(DC-ok, one output): A logic signal is given if the output voltage (main
output in multi-output systems) is below the specified limit. |
---|
Option “m” |
(DC-ok, all outputs): In multi-output systems a logic signal is provided
if the voltage of any output is below the specified limit. |
---|
Option “ac” |
(AC ok) A logic signal connected to relay contacts is given if the
output voltage of an inverter is below the specified limit. |
Option "y" |
(sys-reset): This logic signal is a combination of power fail and DC-ok
as specified for VME systems. |
Option "r" |
(relay): A relay instead of a logic signal is provided for failure
indication. |
PROGRAMMING SEREIS 200-5800, 6600 |
Of output voltage
from 0 to 100% |
By external signal, 0-10Vdc
By external signal, 4-20mA
By 10 turn potentiometer
By 10 turn potentiometer |
eu1
eu2
eu3
eu4 |
Of output current
from 0 to 100% |
By external signal, 0-10Vdc
By external signal, 4-20mA
By 270° potentiometer
By 10 turn potentiometer |
ei1
ei2
ei3
ei4
iso |
Isolating amplifier for programming |
|
|
Programming via interface RS232 or IEEE488 |
|
|
MONITORING SERIES 200-5800, 6600 |
Of output voltage
from 0 to 100% |
By external signal, 0-10Vdc
By external signal, 4-20mA |
mu1
mu2
|
Of output current
from 0 to 100% |
By external signal, 0-10Vdc
By external signal, 4-20mA
|
mi1
mi2 |
Isolating amplifier for programming |
|
iso |
Programming via interface RS232 or IEEE488 |
|
|
CHARGER PROGRAMMING (ALL SERIES) |
Temperature compensated charging voltage(sensor not included) |
tc |
Temperature sensor |
Not interchangeable due to fixed
resistor values |
ts1 |
|
Interchangeable, IC controlled |
ts2 |
Automatic selection of charging characteristic (float / equalize
charge) with timer |
ch1 |
Additionally: Manual selection of charging characteristic |
ch2 |
Additionally: Boost charge operation (manually activated with
time delayed return to normal operation) |
ch3 |
PROGRAMMING / MONITORING- SERIES 6400 |
Programming of output voltage
and current from 0-100%
including isolation |
By external signal, 0-10Vdc
By external signal, 4-20mA |
e1
e2
|
Programming of output voltage
from 0-100% |
By 270° potentiometer
By 10 turn potentiometer
|
eu1
eu2 |
Programming of output current
from 0-100% |
By 270° potentiometer
By 10 turn potentiometer |
ei3
ei4 |
Monitoring of output voltage
and current from 0-100%
including isolation |
By external signal, 0-10Vdc
By external signal, 4-20mA |
m1
m2 |
Remote on/off programming
and monitoring of output
voltage and current from
0-100% including isolation |
By external signal, 0-10Vdc
By external signal, 4-20mA
Via RS232 and IEEE488 |
em1
em2
em3 |
Improved tolerance |
Between reference (external
signal) and measured value /
between measured value and
displayed signal: voltage 0.2%
and current 0.5%. |
tol |
environment |
Option "t" |
(tropical protection):The unit is given additional protection by a heavy
coat of varnish on the printed circuit board(s) and components. |
Option "c" |
(extended temperature range):The circuit is designed and tested for
operation at an ambient temperature as low as –40 °C.
|
Option "ms" |
(increased mechanical strength): Screws are secured by Locktite and
heavy components are fastened by ties and/or glue. Modules with the "ms" option
meet the standard EN61373 regarding shock and vibration. |
mechanics |
Standard mounting |
"Eurocassette" pluggable module for 19" sub-racks 8 |
Option "w" |
(wall mounting): Module is screwed against a mounting plate for
installation in a cabinet. The load connections are typically a terminal block.
|
Option "cha" |
(chassis mount) Module is designed for installation to a structure or
within cabinet. Screw type connectors are supplied with the module. |
Option "din" |
(DIN rail mount) Module is designed for DIN rail mounting to a
structure or within Cabinet. Screw type connectors are supplied with the module. |