Output Model |
DRM-24V80W1PN | DRM-24V120W1PN | DRM-24V240W1PN | DRM-24V480W1PN |
DRM-24V960W1PN |
Operating Temperature |
-25°C to +70°C (Cold start -40°C) |
-25°C to +70°C (Cold start -40°C) |
-25°C to +70°C (Cold start -40°C) |
-25°C to +70°C (Cold start -40°C) |
-25°C to +70°C (Cold start -40°C) |
Storage Temperature |
-40°C to +85°C |
-40°C to +85°C |
-40°C to +85°C |
-40°C to +85°C |
-40°C to +85°C |
Mounting Derating Derate power 2.5%/°C |
Vertical: > 60°C
Horizontal: > 50°C |
Vertical: > 60°C
Horizontal: > 50°C |
Vertical: > 60°C°C
Horizontal: > 50°C |
Vertical: > 60°C
Horizontal: > 40°C |
Vertical: > 60°C
Input: If < 90Vac, > 55°C de-rate1.67%/°C
Horizontal: > 40°C de-rate 1.67%/°C
Input: If < 90Vac, > 35°C de-rate |
Operating Humidity |
5 to 95% RH (Non-Condensing) |
5 to 95% RH (Non-Condensing) |
5 to 95% RH (Non-Condensing) |
5 to 95% RH (Non-Condensing) |
5 to 95% RH (Non-Condensing) |
Shock Test (Non-Operating) |
IEC60068-2-27, Half Sine Wave: 30G for a duration of 18ms; 3 times per direction, 6 times in total |
IEC 60068-2-6, 10Hz to 500Hz @ 30m/S² (3G peak);60 min per axis for all X, Y, Z direction |
IEC60068-2-27, Half Sine Wave: 30G for a duration of 18ms; 3 times per direction, 6 times in total |
IEC60068-2-27, Half Sine Wave: 30G for a duration of 18ms; 3 times per direction, 6 times in total |
IEC60068-2-27, Half Sine Wave: 30G for a duration of 18ms; 3 times per direction, 6 times in total |
Vibration Test (Non-Operating) |
IEC 60068-2-6, Sine Wave: 10-500Hz; 3G peak; displacement of 0.35mm; 60 min per axis for all X, Y, Z directions |
IEC 60068-2-29, 10G (100m/S²) for a duration of 11ms,1,000 times per direction, 6,000 times in total |
IEC 60068-2-6, Sine Wave: 10-500Hz; 3G peak; displacement of 0.35mm; 60 min per axis for all X, Y, Z directions |
IEC 60068-2-6, Sine Wave: 10-500Hz; 3G peak; displacement of 0.35mm; 60 min per axis for all X, Y, Z directions |
IEC 60068-2-6, Sine Wave: 10-500Hz; 3G peak; displacement of 0.35mm; 60 min per axis for all X, Y, Z directions |
Operating Altitude |
0 to 5,000 Meters for ITE application
0 to 2,500 Meters for Industrial application |
0 to 5,000 Meters for ITE application
0 to 2,500 Meters for Industrial application |
0 to 5,000 Meters for ITE application
0 to 2,500 Meters for Industrial application |
0 to 5,000 Meters for ITE application
0 to 2,500 Meters for Industrial application |
0 to 5,000 Meters for ITE application
0 to 2,500 Meters for Industrial application |
Pollution Degree |
2 |
2 |
2 |
2 |
2 |
Bump Test (Operating) |
IEC 60068-2-29, Half Sine Wave: 10G for a duration of 11ms, 1,000 times per direction, 6,000 times in total |
na |
IEC 60068-2-29, Half Sine Wave: 10G for a duration of 11ms, 1,000 times per direction, 6,000 times in total |
IEC 60068-2-29, Half Sine Wave: 10G for a duration of 11ms, 1,000 times per direction, 6,000 times in total |
IEC 60068-2-29, Half Sine Wave: 10G for a duration of 11ms, 1,000 times per direction, 6,000 times in total |
Over Voltage Category |
na |
na |
III : According to IEC/EN 62477-1 / EN 60204-1 (clearance and creepage distances) and IEC 62103 (safety part) |
III : According to IEC/EN 62477-1 / EN 60204-1 (clearance and creepage distances) and IEC 62103 (safety part) |
III : According to IEC/EN 62477-1 / EN 60204-1 (clearance and creepage distances) and IEC 62103 (safety part) |